TM 9-2815-210-34-2-2
b.
Cleaning.
FRAME 1
NOTE
Purpose of agitators to stir cleaning compound while
it is boiling. These steps for fabrication of agitator
are general and may be altered if necessary.
1.
Cut about two feet of copper tube (1) and seal one end (2) by flattening with
hammer.
2.
Coil tube (1) as shown and drill small holes (3) about 1/2 inch apart along
underside of coiled end.
3.
Put fitting (4) on other end of tube (1).
GO TO FRAME 2
4-416