TM 9-2815-210-34-2-2
Table 6-7.
Run-In Schedule - Short (Model LDT-465-1C)
NOTE
During run-in, oil sump temperature shall not
be more than 265°F. Oil pressure is measured
at engine oil gallery.
Gross Brake
Fuel
Duration
Engine Speed
Horsepower
(DF-1 of
Period
(minutes)
(rpm)
(bare engine)
VV-F-800)
1
1
0
0
(minimum)
Prelubricate at 25
psi (measured at
engine oil gallery )
2
10
1200
15
Diesel
3
15
2000
64
Diesel
4
Retighten cylinder head nuts to 157 pound-feet and set valves
immediately following period 3.
5
15
2400
110
Diesel
6
10
2600
125 to 135
Diesel
7
Set high speed adjusting screw to limit maximum speed, no load
2850 to 2900 rpm.
8
Set full load
2600
130 to 140
Diesel
power
(64 lb/hr max.
fuel flow)
9
Power check full
1500
305 pound-
Diesel
load
feet torque
(rein)
(37.5 lb/hr
max. fuel
flow)
10
Set droop screw
1200
(29 to 30 lb/
Diesel
hr fuel flow)
11
Set low idle adjust-
Note 1
0
Diesel
ment
12
As needed to check
Diesel
for leaks
Note 1: Check injection pump data plate for recommended low idle adjustment setting.
6-46