TM 9-2815-210-34-2-2
FRAME 2
1.
2.
3.
4.
5.
6.
7.
NOTE
Fill in standard engine test report form used by the
installation where this test is being done.
Open load control valve (1) until POWER gage (2) reads 15 HP. Close load
control valve.
Set throttle (3) to 1800 RPM on SPEED gage (4).
If POWER gage (2) is above 15 HP, open unload valve (5) to bring it down to
15 HP. Close unload valve.
Reset throttle (3), if needed, to keep 1800 rpm.
Run engine at 1800 rpm at 15 HP for 10 minutes, then write down lubricating
oil pressure and water temperature.
Open unload valve (5) until POWER gage (2) reads 1 to 5 HP.
Stop engine.
GO TO FRAME 3
6-36