TM 9-2815-210-34-2-2
6-5. FLAME HEATER COMPONENT TEST.
NOTE
This task is the same for all intake manifold
flame heater systems. The side - mounted flame
heater system is shown for this task.
a. Flame Heater Fuel Pump Test.
FRAME 1
1.
Take off fuel lines (1) from nozzle (2).
2.
Put fuel line fitting ends (3) into container (4).
3.
Turn heater to ON position for 15 seconds, then turn heater to OFF position.
4.
Check that fuel is in container (4).
5.
If no fuel is in container (4), test and repair flame heater system. Refer to
para 4-58 through 4-80.
6.
If fuel is in container (4), put back fuel lines (1) on nozzle (2).
END OF TASK
6-29