TM 9-2815-210-34-2-2
6-6. BASIC ENGINE RUN-IN.
Be alert at
WARNING
all times during engine operation for
exhaust odors and exposure symptoms. If either
are present, immediately ventilate work area.
Permanent brain damage or death can result from
severe exposure.
Use hearing protection during this test. The
test is very noisy and the noise can cause
damage to your hearing.
a.
Pre-Starting Instructions.
(1) Fill engine crankcase with oil. Refer to LO 9-2320-209-12/1 and
LO 9-2320-211-12.
(2) Open dynamometer
(3) Open dynamometer
FRAME 1
fuel supply valves.
water supply valves.
1.
Turn drain control knob (1) to right until finger tight.
2.
Turn drain control knob (1) to left one turn.
3.
Turn thermostat control knob (2) to right until water can be heard entering
cooling column (3).
4.
When water level in sight glass (4) no longer changes, turn thermostat
control knob (2) to left until it stops.
GO TO FRAME 2
6-31