TM-9-2815-220-24

AVDS-1790 2CA, 2DA and 2DR Air-Cooled 12-Cylinder Diesel Engines

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL FOR AVDS-1790 2CA, 2DA and 2DR Air-Cooled 12-Cylinder Diesel Engines

  TM-9-2815-220-24 - Page 332 of 1563

TM 9-2815-220-24
GENERATOR REPLACEMENT (650 AMPERE)
0051 00
INSTALLATION (Continued)
5. Loosely place V-band clamp (30) all the way
over adapter plate (31) and onto housing (44)
so that it is out of the way, but available for
assembly.
31
44
30
CAUTION
The Ormat generator must be
oriented with the oil inlet fitting
(14) at the 6 o'clock position
(+/- 10°) in order to cool properly.
Failure to comply may result in
premature failure of the generator.
6. Position generator on lifting device, suitably supported, with oil inlet fitting (14) at
approximately the 6 o’clock position.
14
WP 0051 00-10


Back to Top