GENERATOR REPLACEMENT (650 AMPERE)
0051 00
INSTALLATION (Continued)
13. Connect positive cables (1).
a. Honeywell: Connect positive cables (1) to bus bar (5) using screw (2), flat washer (3), and
nut (4).
1
1
4
3
2
5
b. Ormat: Connect positive cables (1) to bus bar (6) using screw (2), flat washer (3), and
nut (4).
6
2
4
3
1
WP 0051 00-14