10. Inspection of the Shield.
a. Inspect shield (1) for cracks or deformation.
b. Replace cracked shield.
03i483m
1
11. Inspection of Dust Detector Cover, Inlet and Outlet Adapters and Filter Retaining Strap.
NOTE
This procedure applies to “clean air” turbo only.
a. Inspect dust detector cover (1) for cracks, scoring of mating surface (2), and thread damage in tapped holes
(3).
b. Check adapters (4) and (5) for cracks, distortion, or thread damage. Ensure both are clear of obstruction.
c.
Inspect filter retaining straps (6) for cracks, bends, and general serviceability.
d. Verify presence of pipe plug (7).
e. Replace any of these components if damaged.
03i484m
7
1
2
3
6
4
5
END OF WORK PACKAGE