TM 9-3990-260-14&P
9-6
Table 9-1. Unit Maintenance Preventive Maintenance Checks and Services - Continued
Item
No.
Interval
Location
Item to
Check/Service
Procedure
Not Fully Mission
Capable If:
1
Semi-
Annually
Twistlocks
a.
Inspect twistlocks (1) for damage or
missing parts. Report damage or missing
parts to supervisor.
b.
Using 4 mm allen wrench, ensure set-
screw in twistlock handle is tight.
c.
Ensure no crack greater than 3/4 inch
(19 mm) exists in the welds or the parent
material of the twistlock housing.
a.
Damage is found that
will impair operation, or any
part is missing.
c.
Twistlock housing or
parent material contains a
crack greater than 3/4 inch
(19 mm).
2
Semi-
Annually
D-rings
Inspect for deformed, cracked, or missing
D-rings (2) and cross bars (3).
Enough damage is found or
enough D-rings are missing
so load cannot be properly
secured.