TM 9-3990-260-14&P
Table 9-1. Unit Maintenance Preventive Maintenance Checks and Services - Continued
Item
No.
Interval
Location
Item to
Check/Service
Procedure
Not Fully Mission
Capable If:
3
Semi-
Annually
Stowage Box
Doors
a.
Check stowage box doors (4) for
bends and dents.
b.
Check that door hinge (5) and
door holder (6) operate correctly and
that stowage box door (4) can be
secured with padlock.
a.
Stowage box door is
bent or will not lay flat.
b.
Door hinge or door
holder are damaged or stow-
age box door cannot be
opened or closed.