TM 9-6920-430-14
(7) Remove the inlet port protective cap (22) from the cross fitting using a
l/2-inch wrench to hold and 9/16-inch to loosen.
(8) Remove the protective plug (23) from the inlet flexible hose fitting (24).
Connect the inlet port (25) of the cross fitting to the inlet flexible hose fitting (24) using a
l/2-inch wrench to hold and a 9/16-inch wrench to tighten. Connect protective plug (23)
to protective cap (22) finger tight.
(9) Remove the protective cap from the cross fitting outlet port (26) using a
l/2-inch wrench to hold and a 9/16-inch wrench to loosen.
(10) Open OUTLET BLEED valve two turns counterclockwise, then fully close
valve.
Change 1 3-23