TM 9-6920-430-14
NOTE
Safety chains omitted for clarity
(11) Remove the protective plug from the loose end of the GPU outlet flexible
hose (27).
(12) Connect the outlet flexible hose (27) to the cross fitting outlet port (26)
using a 1/2-inch wrench to hold and a 9/16-inch wrench to tighten. Connect the loose
protective plug and cap together for cleanliness.
(13) Remove the protective cap from the pressure transducer port (28) of cross
fitting.
(14) Remove the flexible hose (29) from the storage box. Remove one protective
plug from the short hose. Connect the short flexible hose (29) to the pressure transducer
port (28) on the cross fitting using a 1/2-inch wrench to hold and a 9/16-inch wrench to
tighten. Connect the loose protective plug and cap finger tight.
(15) Remove the Pressure Transducer Assembly (30) from the storage box and
place on floor near the right access door of the GPU.
(16) Remove the protective cap from the PRESSURE fitting (31) on the Pressure
Transducer Assembly.
3-24
Change 3