TB 9-2320-302-13&P-1
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
0009 00-6
3
Before
Floor /Fire-
wall Armor
(Left Side)
a. Inspect left side floor and firewall
armor panels for damage or loose or
missing mounting hardware.
Any panel or armor plate is damaged,
bent out of shape, misaligned, loose or
missing, or mounting bolts are loose or
missing.
b. Inspect left side floor and firewall
panels for areas of rust or corrosion.
Any corrosion where area is unsound
and small pin holes are present, or a
rusted through condition is present.
c. Inspect left side floor and firewall
armor panels for cracks near or elon-
gation of bolt holes.
Any cracks that are longer than 1” or
two consecutive bolt holes that are elon-
gated.
d. Inspect left side floor and firewall
armor panels for any holes or gouges.
Any complete penetration of the armor
(hole in the armor) or multiple gouges
1/4” or deeper within 3” of each other.
e. Inspect fuse access panel and support
for damaged, loose, or missing
mounting hardware.
Any damaged to access panel or mount-
ing hardware is loose or missing.
Item
No.
Interval
Location
Procedure
Not Fully Mission
Capable If:
Item To
Check/
Service
417-268