TB-9-2320-302-13-P-1

CREW PROTECTION KIT PART 1 OF 3

TECHNICAL BULLETIN; OPERATOR’S, UNIT AND DIRECT SUPPORT, MAINTENANCE MANUAL, INSTALLATION INSTRUCTIONS, AND REPAIR PARTS AND SPECIAL TOOLS LISTS

NOVEMBER 2006

  TB-9-2320-302-13-P-1 - Page 49 of 380

TB 9-2320-302-13&P-1
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
0009 00-7
ROOF
4
Before
Roof Armor
a. Inspect roof armor panels for damage
or loose or missing mounting hard-
ware.
Any panel or armor plate is damaged,
bent out of shape, misaligned, loose or
missing, or mounting bolts are loose or
missing.
b. Inspect roof armor panels for areas of
rust or corrosion.
Any corrosion where area is unsound
and small pin holes are present, or a
rusted through condition is present.
c. Inspect roof armor panels for cracks
near or elongation of bolt holes.
Any cracks that are longer than 1” or
two consecutive bolt holes that are elon-
gated.
d. Inspect roof armor panels for any
holes or gouges.
Any complete penetration of the armor
(hole in the armor) or multiple gouges
1/4” or deeper within 3” of each other.
Item
No.
Interval
Location
Procedure
Not Fully Mission
Capable If:
Item To
Check/
Service


Back to Top