TB-9-2320-302-13-P-2

CREW PROTECTION KIT PART 2 OF 3

TECHNICAL BULLETIN; OPERATOR'S, UNIT AND DIRECT SUPPORT, MAINTENANCE MANUAL, INSTALLATION INSTRUCTIONS AND REPAIR PARTS AND SPECIAL TOOLS LIST

JUNE 2007

  TB-9-2320-302-13-P-2 - Page 57 of 396

TB 9-2320-302-13&P-2
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
0009 00-11
8
Before
Underbody
Mine Blast
Panel (Right
Side)
Inspect right and center underbody mine
blast panels under cab for damage,
loose, or missing mounting hardware.
Any mine blast panel is damaged or
mounting hardware is loose or missing.
9
Before
Side Armor
(Right Side)
a. Inspect A-pillar and B-pillar armor
panels and door assembly for damage,
loose, or missing mounting hardware.
Any side A-pillar or B-pillar armor or
door assembly is damaged or mounting
hardware is loose or missing.
b.Inspect A-pillar and B-pillar frames
and door assembly frames for areas of
rust or corrosion.
Any corrosion where area is unsound
and small pin holes are present, or a
rusted through condition is present.
c.Inspect door ballistic glass mounting
hardware for damage, loose, or miss-
ing mounting hardware.
Any ballistic glass mounting hardware
is damaged, loose, missing, or mounting
bolts are loose or missing.
d.Inspect exterior surface of door ballis-
tic glass for rock chips, cracks,
scratches, pitting, any damage that
expose glass below the first layer,
cloudiness, or any stickers that impair
vision.
Rock chips, cracks with spider webbing,
scratches, pitting, or damage in the exte-
rior layer of ballistic glass that expose
glass below the first layer, or cloudiness
that impairs vision.
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
Item
No.
Interval
Location
Procedure
Not Fully Mission
Capable If:
Item To
Check/
Service
440-084
UNDERBODY
MINE BLAST PANELS
CENTER UNDERBODY
MINE BLAST PANEL
RIGHT UNDERBODY
MINE BLAST PANEL


Back to Top