TB-9-2350-277-40-P-1

CARRIER, MORTAR, 120-MM M121, SELF-PROPELLED M1064A3

TECHNICAL BULLETIN; INSTALLATION OF CREW II MODIFICATION KIT PART 1 OF 4

JUNE 2009

  TB-9-2350-277-40-P-1 - Page 52 of 100

TB 9-2350-277-40&P-1
INSTALLATION PROCEDURES – Continued
0005 00
0005 00-16
2.
Remove four screws (81), lockwashers (16), washers (15), and enclosure cover (82) from
enclosure assembly (79).
WARNING
Hanging loads, heavy parts, and overhead equipment can fall
unexpectedly.
Falling loads can kill or seriously injure personnel.
Keep away from hanging loads, heavy parts, and overhead
equipment.
Use correct lifting devices to move hanging loads and
heavy parts.
Always have a helper guide you.
Keep your hands and
feet out of confined spaces in which heavy loads are being installed
or removed.
3.
Attach endless sling (80) to enclosure assembly (79) and lift with suitable lifting device.
Position
enclosure assembly (79) on CREW II mount assembly (1).
Have helper assist.
Figure 15.
Enclosure Assembly Cover Removal


Back to Top