TB 9-2350-277-40&P-1
INSTALLATION PROCEDURES – Continued
0005 00
0005 00-13
4.
Adjust RCU cable (33) until it measures 25 inches (63.50 cm) from cable clamp (45) to end of
cable.
5.
Adjust power harness (32) until it measures 20 inches (51 cm) from cable clamp (45) to end of
cable.
6.
Connect P3 lead of power harness (32) to PDA cradle (66).
7.
Tighten all cable clamps and secure cables to existing wiring harnesses as needed with tie
straps.
Figure 12.
RCU/PDA Cable Installation