TM-10-5411-205-13

SHELTER, ELECTRICAL EQUIPMENT - 250/G

TECHNICAL MANUAL; OPERATOR’S, UNIT, AND DIRECT SUPPORT MAINTENANCE MANUAL

MAY 1995
CHANGE 2

  TM-10-5411-205-13 - Page 59 of 127

TM 10-5411-205-13
3-20. Keeper Assembly (cont).
(7)
Check latch torque. Latch torque should be 10 foot-pounds without RFI/EMI gasket or
20 foot-pounds with RFI/EMI gasket. Add or subtract shims (6) to achieve proper
torque. Use same number and thickness of shims with all three keepers.
Figure 3-22. Keeper Assembly Replacement.
3-42 Change 1


Back to Top