TM-10-5411-205-13

SHELTER, ELECTRICAL EQUIPMENT - 250/G

TECHNICAL MANUAL; OPERATOR’S, UNIT, AND DIRECT SUPPORT MAINTENANCE MANUAL

MAY 1995
CHANGE 2

  TM-10-5411-205-13 - Page 64 of 127

paragraph 3-18b.
paragraph 3-18c.
TM 10-5411-205-13
3-23.
Inner Door Assembly (cont).
(5) Louver assembly, holder assembly, and RFI/EMI filter replacement (paragraph
3-24).
(6) Directional vane assembly and air intake falter replacement (paragraph 3-26).
(7) Louver cover assembly latches replacement (paragraph 3-26).
d.
Install.
(1) Coat both sides of each hinge spacer (7) with conductive compound.
(2) Position each spacer (7) and inner door panel (6) in place and secure to outer
door panel with four hex-head screws (3), lock washers (4), and nuts (5).
(3) Position door stay assembly channel (2) in place and secure to inner door panel
(6) with three phillips head screws (1).
(4) Apply a continuous bead of sealer around spacer (7) and hinge bracket, and
around head of screws (5).
Figure 3-25. Inner Door Assembly Replacement.
3-47


Back to Top