TM-5-2350-262-20-2

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL; VOLUME 2 OF 3

  TM-5-2350-262-20-2 - Page 562 of 670

TM 5-2350-262-20-2
NOTE
Step 5 below applies to above illustration.
5.
Route and connect the opposite end of the MCU Power Lead (12491611-1) (2) to the power terminal (3)
on the top of the engine behind the alternator.
Use 5 or 6 Electrical Tie Straps (MS3367-2-0) (1) to
fasten the MCU Power Lead (1) to the right outside of the driver’s compartment where required.
E.
Connecting the Coolant
Umbilical
Assembly
and
Electrical
Leads to the MCU:
NOTE
Steps 1 and 2 below apply to above illustration.
1.
Adjust coolant umbilical (1) and MCU wiring harness power lead (2) so excess umbilical and power lead
are outside and behind the left rear of the driver’s compartment.
2.
Secure the positive electrical lead (3) to the outside of the coolant umbilical (1) with 3 or 4 tie-straps
(MS3367-2-0) (2).