MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. TRACK (LEFT OR RIGHT) WILL NOT TIGHTEN OR LOOSEN, HBF-TT SYSTEM (ELECTRICAL)
Step 13.
Check control box wiring harness for continuity.
Check continuity between connector ends (4 and 8) on control box (3) and control box wiring harness
connector ends (21).
Refer to table 8-10 for lead locations.
If an open circuit is indicated, replace control box wiring harness (22).
Verify that problem is solved.
If continuity is indicated, control box wiring harness (22) is good.