TM 5-2350-377-14&P
HOSE BLOCKAGE TEST
NOTE
Have suitable container ready to catch oil.
•
Disconnect HYDR-MAN-IN-9 hose (4) from tee (6) at port 9 on LH MAN (1).
Plug pressure hose
(4).
Add short hose (7) to tee (6).
•
While holding open end of hose (7) in container, have assistant start engine.
Check for free
flow of hydraulic oil from hose (7).
•
Stop engine; relieve hydraulic pressure.
Disconnect hose (7) from tee (6) and connect HYDR-
MAN-IN-9 hose (4) to tee (6).
0008 00
0008 00-37
PORT 9
6
4
7
8