TM 5-5420-202-20-3
STARTER REPLACEMENT (Sheet 1
PROCEDURE
of 7)
PROCEDURE INDEX
PAGE
Removal
Installation
10-21
10-25
TOOLS
Ratchet with 1/2 in. drive
10 in. extension with 1/2 in. drive
1/2 in. socket with 1/2 in. drive
9/16 in. socket with 1/2 in. drive
3/4 in. socket with 1/2 in. drive
1/2 in. combination box and
open end wrench
3/4 in. combination box and
open end wrench
15/16 in. combination box and
open end wrench
Diagonal cutting pliers
Flat-tip screwdriver
Torque wrench with 3/8 in. drive
(0-200 lb-in.)
3/4 in. socket with 3/8 in. drive
Slip joint pliers
SPECIAL TOOLS: Ground hop kit (Item 31, Chapter 3, Section I)
Wrench, fixed, open end (Item 3, Chapter 3, Section I)
SUPPLIES
Pencil (Item 71, Appendix D)
Seven tags
Lockwire (10 in.) (Item 61, Appendix D)
Glyptol (Item 39, Appendix D)
Gasket
Lockwashers (8 required)
PERSONNEL:
Two
REFERENCES: TM 5-5420-202-10
PRELIMINARY PROCEDURES:
Remove powerplant (page 5-2)
Remove starter low voltage relay
solenoid (page 10-227)
Go on to Sheet 2
TA248962
10-21