TM 5-5420-202-20-3
STARTER REPLACEMENT (Sheet 7 of 7)
11.
12.
13.
14.
15.
16.
Install starter low voltage relay solenoid (page 10-228).
Connect powerplant for ground hop (page 5-26).
Perform operational check (TM 5-5420-202-10).
End of Task
17.
18.
19.
20.
21.
Stop engine (TM 5-5420-202-10).
Using pliers, secure four bracket bolts with
lockwire (AC), exactly as shown in the
figure, to prevent them from loosening.
Coat all exposed terminal fittings with
glyptol.
Disconnect powerplant from ground hop
(page 5-40).
Install powerplant (page 5-14).
TA248968