TM 5-5420-202-20-4
FIXED FIRE EXTINGUISHER OUTSIDE RELEASE HANDLE CONTROL ASSEMBLY
REPLACEMENT (Sheet 4 of 4)
4.
5.
6.
7.
8.
Install first shot control assembly (F) in position (G) on bracket (H).
Install second shot control assembly (J) in position (K) on bracket (H).
Using 9/16 inch wrench, install two nuts (L) securing two control assemblies (F)
and (J) to bracket (H).
Insert two cables (A) in locking plates (M).
Using allen wrench, install screws (N) securing two cables (A) in locking plates (M).
9.
Using
(P) on
pliers, install anti-pilferage seals
exterior handles.
10.
Install release handle body assembly
End of Task
(page
20-41).
TA248705
20-47