TM 5-5420-202-20-4
FIXED FIRE EXTINGUISHER OUTSIDE RELEASE HANDLE CONTROL ASSEMBLY
REPLACEMENT (Sheet 1 of 4)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
20-44
Cleaning and Inspection
20-46
Installation
20-46
TOOLS: 7/64 in. socket head screw key (allen wrench)
5/16 in. open end wrench
9/16 in. open end wrench
Pliers, diagonal cutting
Pliers, long round nose
SUPPLIES:
Seal, anti-pilferage (two required)
PRELIMINARY PROCEDURE:
Remove release handle body assembly (page 20-39).
REMOVAL:
1.
Using allen wrench, loosen eight
screws (A) on lockplates (B)
Go
on to Sheet
2
securing cables together.
2.
Using diagonal cutting pliers, cut two
anti-pilferage seals (C) and pull two
cables (D) with release handle
assemblies (E) out of bracket (F).
TA248702