TM 9-2320-209-20-3-3
FRAME 2
1.
Close light door (1).
2.
Using screwdriver, screw
Follow-on
in and tighten lockscrew (2).
NOTE
Maintenance Action Required:
1.
If 24-volt dome light assembly was worked on,
reconnect battery ground cable. Refer to
Part 1, para 7-58.
2.
If 115-volt dome light assembly was worked on,
turn on 115-volt circuit breaker. Refer to
TM 9-2320-209-10.
END OF TASK
18-362