REMOVAL
NOTE
Have container ready to catch coolant.
1.
Loosen hose clamp (Figure 1, Item 7) and disconnect personnel heater inlet hose (Figure 1, Item 8) from water
manifold shutoff drain valve (Figure 1, Item 6).
2.
Disconnect connector (Figure 1, Item 5) from water temperature sending unit (Figure 1, Item 4) at water
manifold (Figure 1, Item 12).
3.
Disconnect ether cylinder-to-safety valve line (Figure 1, Item 3) and safety valve-to-atomizer line
(Figure
1,
Item
1) from ether start safety valve (Figure 1, Item 2).
NOTE
Clean area around water manifold to prevent dirt or debris from entering cylinder head water
ports when water manifold is removed.
4.
Remove 12 screw assembled lockwashers (Figure 1, Item 13) and manifold (Figure 1, Item 12) from cylinder
heads (Figure 1, Item 11). Discard screw assembled lockwashers.
5.
Remove six gaskets (Figure 1, Item 9) from cylinder head water ports (Figure 1, Item 10). Discard gaskets.
6.
Plug openings on six open cylinder head water ports (Figure 1, Item 10) to prevent dirt from entering water
ports.
TM 9-2320-272-23-2
0290