TM-9-2320-272-23-2

TRUCK, 5-TON, 6X6, M939, M939A1, AND M939A2 SERIES TRUCKS (DIESEL)

TECHNICAL MANUAL; FIELD MAINTENANCE MANUAL; VOLUME 2 OF 5

SEPTEMBER 2012

  TM-9-2320-272-23-2 - Page 435 of 1417

INSTALLATION - Continued
NOTE
Step (22) applies only to vehicles equipped with a transmission PTO.
Transmission connections listed in Steps (22) through (25) can be made through access
door in cab floor.
22.
Install PTO cable (Figure 22, Item 7) and cable pin (Figure 22, Item 8) on select lever (Figure 22, Item 9) with
washer (Figure 22, Item 10) and cotter pin (Figure 22, Item 1), and PTO cable on bracket
(Figure
22,
Item
3) with spacer plate (Figure 22, Item 4), retaining strap (Figure 22, Item 5), two screws
(Figure
22,
Item
6), and nuts (Figure 22, Item 2).
23.
Install transmission oil dipstick (Figure 22, Item 16) in dipstick tube (Figure 22, Item 15).
24.
Install wires (Figure 22, Items 12 and 14) in two spring tension clips (Figure 22, Item 13).
25.
Connect wire (Figure 22, Item 12) to transmission oil temperature sending unit (Figure 22, Item 11).
TM 9-2320-272-23-2
0211
0211-38


Back to Top