ASSEMBLY - Continued
5.
Install water temperature sending unit (Figure 17, Item 5) on water manifold (Figure 17, Item 1).
6.
Install high-temperature switch (Figure 17, Item 2) on water manifold (Figure 17, Item 1), if removed.
7.
Install adapter (Figure 17, Item 3) and shutoff valve (Figure 17, Item 4) on water manifold (Figure 17, Item 1).
8.
Install adapter (Figure 17, Item 7) and shutoff valve (Figure 17, Item 6) on oil cooler (Figure 17, Item 8).
M9372DAA
3
4
5
2
1
7
6
8
Figure 17.
Power Plant Heater Shutoff Valves.
END OF TASK
TM 9-2320-272-23-2
0211
0211-30