INSTALLATION M939A2
NOTE
Male pipe threads must be wrapped with antiseize tape before installation.
1.
Install filter (Figure 3, Item 4) and connector (Figure 3, Item 3) on air tube (Figure 3, Item 14).
2.
Install indicator tube (Figure 3, Item 1) on connector (Figure 3, Item 3) with clamp (Figure 3, Item 2).
3.
Insert indicator tube (Figure 3, Item 1) through firewall (Figure 3, Item 6).
4.
Position grommet (Figure 3, Item 5) on indicator tube (Figure 3, Item 1) and install on firewall
(Figure
3,
Item
6).
5.
Insert indicator tube (Figure 3, Item 1) through instrument panel (Figure 3, Item 13).
6.
Install air cleaner indicator (Figure 3, Item 9) on plate (Figure 3, Item 7) with two screws (Figure 3, Item 11)
and locknuts (Figure 3, Item 12).
7.
Install indicator tube (Figure 3, Item 1) on air cleaner indicator (Figure 3, Item 9) with clamp
(Figure
3,
Item
10).
8.
Install plate (Figure 3, Item 7) and air cleaner indicator (Figure 3, Item 9) on instrument panel
(Figure
3,
Item
13) with four screws (Figure 3, Item 8).
M10261DAA
1
2
3
4
14
13
11
12
10
9
8
7
1
5
6
Figure 3.
Air Cleaner Indicator and Tube Installation.
END OF TASK