INSTALLATION
1.
Coat threads of ether atomizer (Figure 2, Item 1) with antiseize compound and install ether atomizer in adapter
(Figure 2, Item 11).
2.
Tighten ether atomizer (Figure 2, Item 1) until indicator mark is in three or nine o'clock position.
3.
Connect ether supply tube (Figure 2, Item 12) to ether atomizer (Figure 2, Item 1).
4.
Install temperature sensor (Figure 2, Item 6) and ground strap (Figure 2, Item 8) on engine block
(Figure
2,
Item
5) with lockwasher (Figure 2, Item 7), washer (Figure 2, Item 9), and screw
(Figure
2,
Item
10).
5.
Connect wire (Figure 2, Item 4) to wiring harness (Figure 2, Item 3).
6.
Install tiedown straps (Figure 2, Item 2) as required.
M0092DAA
12
1
11
2
3
4
5
7
9
10
6
8
Figure 2.
Ether Atomizer and Temperature Sensor Installation.
END OF TASK