INSTALLATION
WARNING
Top seizing must not be less than 5.0 in. (12.7 cm) from end of cable. Faulty installation will
cause cable failure. Failure to comply may result in injury or death to personnel.
1.
Place cable (Figure 3, Item 1) in vise with 5 1/2 in. (14.0 cm) of cable (Figure 3, Item 1) above jaws of vise.
2.
Measure 5.0 in. (12.7 cm) below end of cable (Figure 3, Item 1). Beginning at this point, wrap 1/2 in.
(12.7
mm) of mechanic's wire (Figure 3, Item 2) around cable toward vise. Twist ends of mechanic's wire
together and bend flat in a groove of cable.
M5236DAA
1
2
5 IN.
5 1/2 IN.
Figure 3.
Front Winch Cable Clevis Installation.
NOTE
If cable is wire-core type, proceed to Step (5).
3.
Unravel six strands (Figure 4, Item 2 and 4) of cable (Figure 4, Item 3) above vise.
4.
Cut off hemp core (Figure 4, Item 1) as close to vise as possible.
TM 9-2320-272-23-4
0675
0675-4