7-3. Disassembly.
a.
If lamps are to be replaced, remove five screws (1, fig. 7-4) from the cover (2) and remove the
cover and dial.
b.
Disconnect the white wire from the terminal strip (located on the bottom right front),
c. Remove four screws (4) that mount housing (3) to the bracket. Remove the housing.
d. Remove nine screws (5) that hold shield (6) to the cover (7). Remove the shield. Remove two
screws from terminal strip and remove terminal strip, designation plate and grommet.
TA 074055
Figure 7-4. Remove Housing and Cover.
7-5