TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 586 of 1318

TM 9-2320-328-13&P-1
0067-6
DRAFT
0067
HWT0668A
Step 9.
Put pump operator’s panel REEL DISCHARGE switch to CLOSED position (WP 0004).
Pull battery disconnect switch to off position (WP 0007).
Disconnect main wire harness
pump operator’s panel 27-pin wire harness connector.
With a test lead set, check for
continuity across main wire harness wire 4098 (green) from main wire harness pump
operator’s panel 27-pin wire harness connector, terminal 16 to main wire harness pump
house wire harness connector, terminal 5.
a.
If there is continuity, repair wire 4098 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
b.
If there is no continuity, repair wire 4098 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0292).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top