TM 9-2320-328-13&P-1
0067-7
DRAFT
0067
HWT0660A
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 10.
Open pump operator’s panel (WP 0207).
Check for 22 to 28 VDC between pump
operator’s panel wire harness wire 2834 (red) at REEL DISCHARGE switch terminal
and a known good ground.
If 22 to 28 VDC are not present, repair wire 2834 in pump operator’s panel
wire harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
Step 11.
Pull battery disconnect switch to off position (WP 0007).
Put pump operator’s panel
REEL DISCHARGE switch to OPEN position (WP 0004), check for continuity across
REEL DISCHARGE switch from terminal to terminal.
a.
If there is continuity, repair wire 4098 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
b.
If there is no continuity, replace REEL DISCHARGE switch (WP 0220).
Step 12.
Put pump operator’s panel PUMP COOLER switch to ON position (WP 0004).
Check if
cab PUMP COOLER indicator illuminates.
If cab PUMP COOLER indicator does not illuminate, go to Step 15.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION