TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 582 of 1318

TM 9-2320-328-13&P-1
0067-2
DRAFT
0067
HWT0804A
Step 2.
Push battery disconnect switch to on position (WP 0007).
Put pump operator’s panel
PUMP COOLER switch to ON position (WP 0004).
Check if pump operator’s panel
PUMP COOLER indicator illuminates.
If pump operator’s panel PUMP COOLER indicator does not illuminate, go
to Step 12.
HWT0655
Step 3.
Put PUMP COOLER switch to OFF position (WP 0004).
Remove pump house panel G
(WP 0339).
Inspect air lines from air control valve manifold to hose reel discharge valve
for kinks and damage.
If air lines are kinked or damaged, replace damaged air lines (WP 0374).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION