0066
HWT0468
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 1.
Open pump house access door assembly (WP 0009).
Check if hose reel rewind circuit
breaker is tripped.
If hose reel rewind circuit breaker is tripped, reset circuit breaker.
Step 2.
Disconnect batteries (TM 9-2320-325-14&P).
Check for continuity across hose reel
rewind circuit breaker from terminal to terminal.
If there is no continuity, replace hose reel rewind circuit breaker (WP 0252).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION