TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 567 of 1318

TM 9-2320-328-13&P-1
0065-11
DRAFT
0065
HWT0488A
Step 13.
Install circuit breaker P9 (WP 0262).
Open pump operator’s panel (WP 0207).
Disconnect pump operator’s panel wire harness DRIVER SIDE AUX. INLET valve
control connector.
Push battery disconnect switch to on position (WP 0007).
Check for
22 to 28 VDC between pump operator’s panel wire harness wire 4097 (orange) at
DRIVER SIDE AUX. INLET valve control connector, terminal A and a known good
ground.
If 22 to 28 VDC are not present, go to Step 15.
Step 14.
Pull battery disconnect switch to off position (WP 0007).
With a test lead set, check for
continuity across wire 3895 (black) from pump operator’s panel wire harness DRIVER
SIDE AUX. INLET valve control connector, terminal B and a known good ground.
a.
If there is continuity, replace DRIVER SIDE AUX. INLET valve
control (WP 0209).
b.
If there is no continuity, repair wire 3895 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top