TM 9-2320-328-13&P-1
0065-7
DRAFT
0065
NOTE
•
Do not engage PUMP PTO during procedure.
Valve operations cab be checked without
water pump operations.
•
Valve motor operation can be checked either by noting vibration of valve assembly, or by
observing rotation of 7/16” hex at end of valve drive assembly worm gear shaft.
•
Do not remove cap from DRIVER SIDE AUX. INLET.
Water may be released from system
when valve is operated.
Step 9.
Push battery disconnect switch to on position (WP 0007).
While an assistant pushes
pump operator’s panel DRIVER SIDE AUX. INLET valve control OPEN and CLOSE
buttons
(WP 0004), check if DRIVER SIDE AUX. INLET valve control THROTTLED
(yellow) indicator illuminates and driver side auxiliary inlet valve motor operates.
If indicator illuminates and valve motor operates, replace driver side
auxiliary inlet valve drive assembly
(WP 0248).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION