TM 9-2320-328-13&P-2
0125-7
DRAFT
0125
Change 1
.
HWT1486
.
NOTE
Steps 9 and 10 checks cab power distribution wire harness wires 1052 (brown) and 1053
(orange) for a short to ground.
.
Step 9.
Pull battery disconnect switch to off position (WP 0007). Put EMERG MASTER switch
to off position (WP 0004). With a test lead set, check for continuity (short to ground) of
power distribution wire harness wire 1052 (brown) from cab power distribution wire
harness siren control MP2 connector, terminal A to a known good ground.
.
If there is continuity, repair wire 1052 in cab power distribution wire harness
if repairable (TM 9-2320-325-14&P), or replace cab power distribution wire
harness (WP 0280).
.
Step 10.
With a test lead set, check for continuity (short to ground) of power distribution wire
harness wire 1053 (orange) from cab power distribution wire harness siren control MP2
connector, terminal C to a known good ground.
.
a.
If there is continuity, repair wire 1053 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness (WP 0280).
.
b.
If there is no continuity, replace siren control (WP 0380).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION