TM 9-2320-328-13&P-2
0125-1
DRAFT
0125
Change 1
FIELD LEVEL MAINTENANCE
SIREN DOES NOT OPERATE PROPERLY
INITIAL SETUP:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
.
SIREN DOES NOT OPERATE PROPERLY
.
HWT1488
.
Step 1.
Push battery disconnect switch to on position (WP 0007). Put EMERG MASTER switch
to on position (WP 0004). Put siren control selector switch to WAIL, YELP, and HI-LO
(WP 0004). Check if siren operates.
.
If siren operates in at least one mode, but not all, replace siren
control (WP 0380).
Tools and Special Tools
Lead Set, Test (WP 0398, Item 14)
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
References
TM 9-2320-325-14&P
WP 0004
WP 0007
WP 0104
WP 0205
WP 0242
References (continued)
WP 0273
WP 0280
WP 0292
WP 0349
WP 0380
WP 0400
Equipment Conditions
Engine OFF (TM 9-2320-422-10)
Wheels chocked (TM 9-2320-422-10)