TM 9-2320-328-13&P-2
0125-5
DRAFT
0125
Change 1
.
HWT0319
.
Step 6.
Install circuit breaker FS 6 (WP 0242). Disconnect cab power distribution wire harness
siren control MP2 connector. Push battery disconnect switch to on position (WP 0007).
Put EMERG MASTER switch to on position (WP 0004). With a test lead set, check for
22 to 28 VDC between wire 1637 (red) at cab power distribution wire harness siren
control MP2 connector, terminal F and a know good ground.
.
If
22 to 28 VDC are not present, repair wire 1637 in cab power distribution
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution harness (WP 0280).
.
Step 7.
Pull battery disconnect switch to off position (WP 0007). Put EMERG MASTER switch
to off position (WP 0004). With a test lead set, check for continuity across cab power
distribution wire harness wire 1640 (black) from cab power distribution harness siren
control MP2 connector, terminal D to a known good ground.
.
If there is no continuity, repair wire 1640 in cab power distribution wire
harness (TM 9-2320-325-14&P), or replace cab power distribution wire
harness (WP 0280).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION