TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 434 of 1390

TM 9-2320-328-13&P-2
0153-4
DRAFT
0153
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12. Remove hose (26) from fitting (27).
13. Remove hose (26) from fitting (28).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Fitting and orifice fitting must be removed in order to provide clearance when removing
screws.
Note position of elbows and fittings prior to removal to ensure proper installation.
14. Remove orifice fitting (29) and fitting (28) from power take off (18).
HWT2206
HWT2207