TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 890 of 1390

TM 9-2320-328-13&P-2
0251-2
DRAFT
0251
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Remove nut (4), washer (5), and high amperage cable (2) from pump house B+ stud (6).
5.
Remove high amperage cable (2) from vehicle.
END OF TASK
INSTALLATION
NOTE
•
Route high amperage cable as noted prior to removal.
•
Install cable ties, split loom, and cushion clips as required.
1.
Install high amperage cable (2) on vehicle.
2.
Install high amperage cable (2) on pump house B+ stud (6) with washer (5) and nut (4).
3.
Close passenger side pump house control access door (WP 0008).
HWT2356