TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 893 of 1390

TM 9-2320-328-13&P-2
0252-1
DRAFT
0252
FIELD LEVEL MAINTENANCE
HOSE REEL CIRCUIT BREAKER REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove locknut (1) and wire (2) from circuit breaker (3).
Discard locknut.
2.
Remove locknut (4) and wire 1296580 (5) from circuit breaker (3).
Discard locknut.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2429
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Compound, Sealing (WP 0400, Item 10)
Tags, Identification (WP 0400, Item 23)
Ties, Cable, Plastic (WP 0400, Item 26)
Locknut (1)
Locknut (1)
Lockwasher (2)
Lockwasher (2)
References
WP 0254
WP 0391, Fig. 40
Equipment Conditions
Pump house panels E removed (WP 0339)
Pump house access door opened (WP 0009)


Back to Top