CONTINUITY TEST
Function/Solenoid
Terminal Board (+) Position
Solenoid Resistance in Ohms
Underlift fold up - L18
2
81-101
Stinger in - L13
Main winch speed LH high
3
4
6
8
11
12
13
14
15
16
17
81-101
81-101
81-101
81-101
81-101
81-101
81-101
81-101
81-101
Underlift up - L14
Main winch LH in - L6
Main winch RH in - L1
Main winch RH out - L2
Main winch speed RH high
Main winch LH out - L5
Underlift down - L11
Stinger out - L16
Underlift fold down - L15
35-45
35-45
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
terminal listed in Table 2-14. Actuator
Solenoid Resistance Test.
(3)
Connect negative (-) probe of multimeter on
terminal block TB-C and note reading on
multimeter.
(4)
If resistance is less or greater than value
listed in Table 2-14. Actuator Solenoid
Resistance Test, notify DS Maintenance.
(5)
Install wrecker control panel top cover
(para 17-20).
TABLE 2-14. ACTUATOR SOLENOID RESISTANCE TEST