TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1463
2-1463
2-1463
2-1463
2-1463
CONTINUITY TEST
Underlift fold up
Stinger in
Underlift up
Main winch LH in
Main winch RH in
Main winch RH out
Main winch speed RH high
Main winch LH out
Main winch speed LH high
Underlift down
Stinger out
Underlift fold down
Emergency stop
UP
IN
UP
IN
IN
OUT
HIGH
OUT
HIGH
DOWN
OUT
DOWN
KILL
Function
Remote Control Box Position
P2 Pin
Positive (+)
c
c
c
c
c
c
c
c
c
c
c
c
a
P2 Pin
Negative (-)
e
f
g
d
b
Y
X
W
V
U
T
S
Z
TABLE 2-15. REMOTE CONTROL BOX CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
pin listed in Table 2-15. Remote Control Box
Continuity Test.
(3)
Connect negative (-) probe of multimeter to
pin listed in Table 2-15. Remote Control Box
Continuity Test.
(4)
Position remote control box switch to position
listed in Table 2-15. Remote Control Box
Continuity Test and note reading on
multimeter.
(5)
If continuity is not present, go to step 4 of this
fault.
(6)
If continuity is present, repair wire (para 2-45)
or replace M1089 remote control wiring
harness (para 7-117).