TM-9-2320-366-20-5

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 5 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-5 - Page 125 of 1158

TM 9-2320-366-20-5
(4) Remove 90 degree fitting (2) from air chamber (8).
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to
comply
may
result
in
injury
to
personnel.
(1) Apply antiseize compound to threads of 90-degree fitting
(1).
(2) Position 90-degree fitting (1) in air chamber (2).
(3) Tighten 90-degree fitting (1) approximately 2 1/2 turns
past hand tight.
17-83


Back to Top