TM 9-2320-366-34-3
17-14.8
Change 2
17-3.
M1090/M1094 FOUR-WAY RELIEF VALVE REPLACEMENT/REPAIR (CONT)
(7)
Install preformed packing (12), two back up rings
(13), and preformed packings (14) on flow control
valve (15).
(8)
Position flow control valve (15) in valve body (5).
(9)
Tighten flow control valve (15) to 80-90 lb-ft (108-
122 N•m).
(10) Install preformed packing (16), back-up ring (17),
preformed packings (18 and 19), and back-up ring
(20) on pressure reducing valve (21).
(11) Position pressure reducing valve (21) in valve body
(5).
(12) Tighten pressure reducing valve (21) to 35-40 lb-ft
(47-54 N•m).
(13) Install preformed packings (22 and 23) and back-
up ring (24) on check valve (25).
(14) Position check valve (25) in valve body (5).
(15) Tighten check valve (25) to 35-40 lb-ft (47-54
N•m).
(16) Install preformed packing (26), back-up ring (27),
and preformed packing (28) on relief valve (29).
(17) Position relief valve (29) in valve body (5).
(18) Tighten relief valve (29) to 50-55 lb-ft (68-75 N•m).